Product Type | | |
Contact Arrangement | | 2NO
|
Incorporated reed switch: Bestact type
| R15 |
Contact Performance | Making Capacity | 115VDC 20A (L/R≧5ms) Current-Carrying time: 0.5s
|
Breaking Capacity | 115VDC 0.5A (L/R=100ms)
|
Rated Operational Current (Inductive Load) | 240VAC 1A(50/60Hz) 115VDC 0.5A, 240VDC 0.2A(L/R=100ms) |
Minimum Operational Power Ratings | 24VDC 1mA Failure Rate λ₆₀=4.6×10⁻⁹(/time)or less |
Initial Contact Resistance | 500mΩ or less(6VDC 1A) |
Operating Time | 5ms or less (excluding bounce time)
|
Releasing Time | |
Bounce Time | 3ms or less |
Rated Insulation Voltage | AC250V(50/60Hz) |
Insulation Resistance | Across open contacts, between contacts, between coil and contact, and between terminals and ground : 100MΩ or greater (with 500VDC Megger)
|
Rated Impulse Voltage | Between contacts, and between coil and contact : 4500V(1.2/50μs) |
Withstand Voltage
| Across open contacts: 1000VAC, 1 min (50/60Hz) Between contacts, between coil and contact, and between terminals and ground : 2200VAC, 1 min (50/60Hz)
|
Vibration Resistance | Malfunction: 98m/s² {10G} (20 to 1000Hz)
|
Shock Resistance
| Malfunction : 147m/s² {15G}, Destruction : 980m/s² {100G}
|
Operating Temperature
| |
Storage Temperature
| -40℃ to +80℃
|
Approx. Weight | 130g | 60g |
Note:
1. The contact performance specifications refer to the built-in contacts.
2. The rated operational current indicates the current value to be used under the rated operational voltage and specified conditions (make and break current, switching frequency, and electrical endurance).
For 240VAC: The setting is based on 10× make (cosφ = 0.6–0.7) and 1× break (cosφ = 0.3–0.4). A rated operational current of 1A means 10A for making and 1A for breaking. For 115VDC: The setting is based on 1× make and 1× break, specified for inductive loads (L/R = 100ms).
3. Time characteristics are measured under the following conditions: rated coil voltage applied, no flywheel diode connected, and an ambient temperature of 20℃.
4. Temperature characteristics are values under conditions without freezing or condensation.